Mecanco.com

MECANCO Header

THE MALL PROJECT ( TWIN CONE )

Full Width Image
MECANCO Tensile Structure
Twin Cone Membrane Structure
CONICAL MEMBRANES

TWIN CONE

A bespoke twin cone, fixed edge tensile membrane structure, precision-engineered to cover the central plaza atrium of a large commercial mall.

Anchored by two dominant central masts, the structure features a classic conical form on each mast with all boundary edges firmly clamped to the duct perimeter — creating a taut, architecturally refined roofing envelope over a rectangular atrium duct.

The geometry of each cone was meticulously defined in response to the existing structural drawings and site-specific CAD data, ensuring a seamless integration with the building's architecture.

The valley formed between the two cones was subject to rigorous water ponding analysis, ensuring zero water accumulation and long-term weatherproofing performance.

Each cone apex is finished with a high-durability FRP cap, protecting the structural tip while delivering a clean, polished termination detail.

Twin Cone Tensile Membrane Structure
Twin Cone Statement

Twin cones rising above the heart of the mall — where engineering shelters commerce and architecture inspires experience.

Twin Cone Mall Structure
Application & Utility
APPLICATION & UTILITY

Sheltering Commerce.
Elevating Experience.

Designed as the primary overhead roofing solution for the central plaza atrium of a busy commercial mall, this twin cone tensile membrane transforms the heart of the building into a sheltered, light-filled, visually dynamic space.

The structure provides year-round weather protection to the mall's central gathering zone, enabling continuous commercial activity beneath an architecturally striking canopy.

As the centrepiece of the mall's interior landscape, it also serves as a powerful visual identity element — elevating the overall aesthetic and customer experience of the entire property.

Twin Cone Application and Utility
Technical Specifications
TECHNICAL SPECIFICATIONS

Engineered For
Precision Performance

Structure Type Twin cone, fixed edge tensile membrane
Structural System Dual central mast with full perimeter boundary clamping
Membrane Material Type 2 PVDF Coated Tensile Membrane
Apex Finishing High-durability FRP (Fibre Reinforced Polymer) cone caps
Geometry Custom, non-modular — designed as per site-specific CAD drawings and duct dimensions
Engineering Analysis Structural load analysis and water ponding simulation conducted and validated
Installation Level Elevated top terrace level execution
Twin Cone Technical Specifications
Our Edge
OUR EDGE

Reimagining Vision.
Delivering Without Compromise.

When the client and architect initially envisioned a conventional polycarbonate dome over the atrium duct, MECANCO saw a greater opportunity.

Our team presented alternative design render options that reimagined the space entirely — and the response was immediate appreciation.

The proposed twin cone tensile solution was approved by the client, architect and project consultants, replacing a generic solution with one that is architecturally distinctive, structurally superior and functionally enduring.

Executed at significant elevation on the building's top terrace, this project demanded exceptional precision and site management — both of which MECANCO delivered without compromise.

Today, the mall operates under our membrane roof, a living testament to what thoughtful design engineering can achieve.